Weather Compensation
Weather compensation controllers measure the temperature outside the building and vary the temperature of the water pumped into the heating systems accordingly. A weather compensated system will provide building occupants with increased comfort levels whilst also reducing the amount of energy consumed as the boiler will fire less often as the system water temperature will be at a lower level.
Radiant Control offer a range of units for single to multiple weather compensated temperature systems. Each unit is supplied complete with outdoor and mixed flow sensors, some units have additional boiler flow sensors.
….
.
.
.
| Controller | Variable Temp System | Sensors | Mixing Method | DHW Control | ||||
| Outdoor | Boiler |
Mixed flow |
Floating action valve |
0-10 Vdc |
Speed Injection pump |
|||
| 355x Controller | Single | yes | yes | yes | yes | Yes | ||
| Single | yes | yes | yes | yes | ||||
| Single | yes | yes | yes | yes | ||||
| 363e Controller | Two | yes | yes | yes | yes | yes | ||
| 374e Controller | Three | yes | yes | yes | yes | |||
Need help selecting the correct unit for your requirements? Call our technical advice team on 01530 519666 or send us an email.
-

Weather Compensation 355x Controller
The 355x Controller is a weather compensation unit with a single variable temperature system, it is supplied complete with outdoor and mixed flow sensors. The mixing method utilises valves with either a ‘floating’ action or 0-10 Vdc. The Mixing Control 355x regulates the supply water temperature of an automated mixing valve in order to provide outdoor reset or setpoint operation. The 355x Weather Compensator provides a floating action or a 0-10 V (dc) signal to adjust the mixing valve position; it also includes two separate night setback channels when used with kanmor 500 series thermostats.
[View Weather Compensation 355x Controller] -

Weather Compensation 360e Controller
The 360e Controller is a Weather compensation unit with a single variable temperature system. It is supplied complete with outdoor, boiler flow and mixed flow sensors. The mixing method utilises valves with a ‘floating’ action. The Mixing Control 360e is designed to control the supply water temperature to a hydronic system in order to provide weather compensation or setpoint operation. The control uses a floating action mixing valve to regulate the supply water temperature, while protecting the boiler against flue gas condensation. The control has a Liquid Crystal Display (LCD) to view system status and operating information.
[View Weather Compensation 360e Controller] -

Weather Compensation 361e Controller
The 361e Controller is a Weather compensation unit with a single variable temperature system. It is supplied complete with outdoor, boiler flow and mixed flow sensors; the mixing method utilises a variable speed injection pump. The Mixing Control 361e is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset or setpoint operation. The control uses a variable speed injection pump to regulate the supply water temperature, while protecting the boiler against flue gas condensation. The control has a Liquid Crystal Display (LCD) to view system status and operating information.
[View Weather Compensation 361e Controller] -

Weather Compensation 363e Controller
The 363e Controller is a Weather compensation unit with two variable temperature systems and Domestic Hot Water (DHW ) control. It is supplied complete with outdoor, boiler flow and mixed flow sensors. The 363e uses a floating action output signal to control the position of a mixing valve.
[View Weather Compensation 363e Controller] -

Weather Compensation 374e Controller
The 374e Controller is a Weather compensation unit for three variable water temperature applications and Domestic Hot Water (DHW) control. It is supplied complete with outdoor, boiler flow & mix flow sensors.
[View Weather Compensation 374e Controller]